Maliy pr. V. O., 62/2, liter A, St. Petersburg, Russian Federation, 199178

Control panels

The Control panels are designed for connecting AC induction motors to the supply circuit and for starting, protecting and shutting them off.

VIBROTECHNIK manufactures two types of control panel: MCP with a metal housing and PCP with a plastic housing.

The PCP control panel is designed for tabletop equipment in laboratories.

The MCP control panels are designed for large items operating under severe conditions. The MCP has modifications designed for control of process units consisting of several equipment items: the CMCP with two pushbutton posts.

Characteristics PCP1 PCP3 MCP1 MCP3 CMCP MCPU1 MCPU3
Compatible equipment models DG 65 VCM 10, VG 1, VG 6, SG 1 VD 50, CDU SM 50.0, VD 50,  JC 6M, CDC, DG 175, DG 200, HC 2x2, JC 10M, DRC,  DG 250,  CM 250, JC 15  CDU with JC 6(M)
CDU with JC 10(M)
CDU with JC 15
CDU with DG 175M
CDU with DG 200M
CM 250 with CDC,  HC 2x2 with CDC
 CM 120M with VF 1,
VD 50 with VF 1, CSU,
CDU +VF1
CDU +VF2
CSU,
VD 50, CM 120M,
DG 175, DG 200,
DG 250, DRC, with VF 1/VF 2,  
CDU with DG 175M/200M+VF1
50 Hz supply voltage, V 220 380 220 380 220 380
Circuit breaker current, A 4 2-6,3 6-13 3-20 5-25 4-13 1-10
Thermal overload relay current, A 3,2 1,6-3,2 5-10 2,5-16 0,63-20 5-10 0,63-8,5
Overall dimensions (Length x Width x Height), mm 205х185х130 340х240х170
Weight, kg 2,0 5,0

Advantages of VIBROTECHNIK Control panels:

  • IP 54 dust and moisture resistance rating;
  • Complies with IЕС 60439- 1:2004 “Low Voltage Distribution and Control Components”;
  • Automatic power shutoff if the maximum permissible current is exceeded or a short circuit occurs;
  • Two fuses to protect control circuit elements;
  • When limit microswitches and an emergency stop button are connected, the motor is inhibited if the equipment operating rules are violated;
  • The MCP has a tall post for floor mounting, while the PCP has a short post for tabletop mounting;
  • Marking and assembly of control circuit wires in a bundle;
  • The MCP housing and cover are made of metal 1.5 mm thick;
  • The PCP housing is made of impact-resistant plastic;
  • Visual observation of the position of the thermal overload relay button and circuit breaker handle through the transparent cover of the PCP.